Siemens 3TF3500-0A..ZT00^ 40A Power Contactors SICOP 3TF AC coil 230V Size 2

Siemens 3TF3500-0A..ZT00^ 40A Power Contactors SICOP 3TF AC coil 230V Size 2

₹ 6,255.00

₹ 7,380.90+18% GST

Freight Extra (Godown Delivery)

Brand

Siemens

Seller SKU

TNB-0505-230 V

Quantity

Min 1 • Stock 200

Product Specification

Product NameSiemens 3TF3500-0A..ZT00^ 40A Power Contactors SICOP 3TF AC coil 230V Size 2
BrandSiemens
Product CodeTNB-0505-230 V
Country of ManufacturerIN
Weight1.000
CategoryPower Contactor
Coil Voltage230 V

Product Description

Siemens 3TF3500-0A..ZT00^ 40A Power Contactors SICOP 3TF AC coil 230V Size 2 - Strategic Industrial Guidance

Siemens 3TF3500-0A..ZT00^ 

Siemens 3TF3500-0A..ZT00^ 40A Power 

Siemens 3TF3500-0A..ZT00^ 40A Power Contactors SICOP 3TF AC coil 230V Size 2

 

Applications

3Tf Power Contactors Are Suitable For Switching And Controlling
Squirrel Cage And Slip-Ring Motors As Well As Other Ac Loads,
Such As Solenoids, Capacitors, Lighting Loads, Heating Loads And
Transformer Loads. 

 

Standards

Contactors Conform To Is/Iec 60947-4-1. They Also Carry The Ce
mark.

 

Coordinated feeder

Contactors And Bi-Relays Have Been Tested For Type-2 Coordination
At Iq = 50Ka, 415V Ac, 50Hz As Per Is/Iec 60947-4-1, For Both
Fuse Protected As Well As Fuseless Motor Feeders.

 

Range

Air Break Contactors Are Available From 9 A To 475A In 3 Pole
Version.

Also Available In 2 Pole Ac Version From 45A To 400A.

 

Technical Data

Contactor Size 2
Type 3TF35
Permissible Ambient Temperature Storage
Service
°C -55 to +80
°C
-25 to +55
Maximum operating voltage V 690
Rated insulation voltage Ui (At Pollution Degree 3)1) V
690
Rated impulse strength Uim kV 8
Mechanical endurance (make/break operations) AC Cycles 10x10
Rating of contactors for AC loads
AC-1 duty, switching resistive load
Rated operational current Ie at 40°C upto 690V A 65
at 55°C upto 690V A
55
Ratings of three-phase loads  p.f.=1 at 55°C at 415V kW 36
500V kW 47.5
690V kW 62.7
AC-2 and AC-3 duty
Rated operational current Ie2) upto 415V A 38
500V A 38
690V A 27
Nominal rating of slipring or squirrel-cage motors at 50/60 Hz. at 415V kW
18.5
500V kW 25
690V kW 23
AC-4 duty (contact endurance approx. 2x105 make-break operations at Ia=6Ie)
Rated operational current Ie upto 690V A 18.5
Rating of squirrel-cage motors at 50/60Hz. at 415V kW 9.8
500V kW 11.8
Max. permitted rated operational current Ie/AC-4 = Ie/AC-3 upto 500V. Ref. life curve for the life. 690V kW 15.5
Used as stator contactor (upto 690V) (AC-2 duty)
Stator currents Ies 20% A
85
On-load factor (ED)3) with intermittent duty 40% A 67
60% A 60
* Applicable up to 500V 80% A 55
Used as rotor contactor (upto 690V) (AC-2 duty)
Rotor current Ier 20% A 125
On-load factor (ED)3)
with intermittent duty
40% A 106
60% A 95
80%
A 87
Locked rotor voltage Uer Starting V 1320
Plugging / Control V 660
AC-6b duty, switching low-inductance individual three-phase capacitors at 50/60Hz4) (we also offer special capacitor duty contactors) 415V kVAR 16.7
500V kVAR 16.7
690V kVAR 16.7
Thermal loading 10 s current A 400
Power loss per current path at Ie/AC-3 W 2.5

Returns & Cancellation

Returns Policy:

1. Once orders are placed, cancellations are not permitted.

2. Payments for orders will not be adjusted or refunded in case of cancellation.

Shipping & Delivery Policy:

1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If buyer and seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.

2. Shipping freight costs will be additional and based on actuals, to be borne by the buyer.

3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis.

4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.

Feedback

You're reviewing: Siemens 3TF3500-0A..ZT00^ 40A Power Contactors SICOP 3TF AC coil 230V Size 2

Your Rating *