| Product Name | Continuous Emission Monitoring System EE-CEMS-SPN-N-03 (Sox, Nox, CO, SPM) |
| Brand | Unknown Brand |
| Product Code | ENE-0004 |
| Country of Manufacturer | IN |
| Weight | 1.000 |
| Category | Emission Monitoring System |
| Test Certificate | No |
| Model | EE-CEMS-SPN-N-03 |
E&E Solutions' CEMS Serves As A Device Meant For Accurately And Consistently Monitoring Airborne Contaminants. It Gauged In Real-Time Many Aspects Like Nox, Sox, CO, CO2, O2 And SPM Among Others. CEMS Has Prominent Characteristics Of Internet Based Online Calibration System, Cloud-Computing Connectivity Plus Instant Responses On Data Generated Thus Leading To Upholding Compliance With Environmental Laws Plus Preventing Air Pollution Standards Violations. To Make It An Indispensable Instrument For Environmental Control Within Factories, Its Long Lifespan Durability Coupled With Low Maintenance Requirements And User-Friendliness Put It On Top Position.
Features
Applications
| Product Specification | |
| Parameters measured | SPM, SOx, NOx, CO, CO2, O2 |
| Working temperature | -20°C to 40°C |
| Storage temperature | -40°C to 60°C |
| Ambient temperature Range | -20°C to 60°C |
| Technology NDIR | |||
| Performance Specification | Working Parameters | ||
| Measurement | Sox, NO, CO, CO2, O2 | Working temperature | 0-50°C |
| Precision | ±2%FS | Rtelative humidity | 0-90°C |
| Repeatability | ±1%FS | Sampling gas pressure | <101kPa |
| Stability | <±2%FS/24h | Sampling Gas flow rate | 0.7-1.2 L/min |
| Life span | 3 years (in air) | ||
| Performance Specification | |
| Measurement | Solid Particles |
| Particulate Size | 0.3 um or larger |
| Range | 0.1 mg/m³ to 1kg/m³ |
| Ambient Condition | |
| Temperature | -20 to +45°C |
| Humidity | 95% RH (non- condensing) |
| Vibration | 5m/2 or less |
| Power Supply | 115 VAC or 230 VAC or 24 VDC |
| Power Consumption | 8W AC models, 3W 24 VDC mode |
| Working Parameters | |
| Temperature | Max 100°C |
| Pressure | Max 200kPa |
| Gas velocity | Min 4m/s |
| Humidity | 95% RH or less |
| Input surge voltage | Max 100V |
| Measurement principle | Electrostatic charge detection |
| Output damping time | 10 to 180 sec |
| Output signal | Isolated 4-20mA |
| Sensor Specification | ||||
| Parameter | Technology | Range | Operating Temp. | Resolution |
| SPM | Tribo Opacity | 0-1000 mg/Nm3 0-800 mg/Nm3 | 10-500°C | 0.1 mg/Nm3 |
| SOx | NDIR | 0-1000 PPM | 0-45°C | 1 PPM |
| NO | NDIR | 0-1000 PPM | 0-45°C | 1 PPM |
| CO | NDIR | 0-1000 PPM | 10-45°C | 1 PPM |
| CO2 | NDIR | 0-5000 PPM | 0.1°C | 1 PPM |
| O2 | NDIR | 0-20 % | 0-45°C | 0.01% |
| Power Source | |
| Specification Power Supply (Main Board) | 220-250 Volts |
| Cooler Voltage | 110/220V AC |
| Frequency | 50 Hz |
| Watt | 80-100W |
| Sox Compressor | 220 Volts |
Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2. Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If buyer and seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2. Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis.
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
You're reviewing: Continuous Emission Monitoring System EE-CEMS-SPN-N-03 (Sox, Nox, CO, SPM)
Your Rating *
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.