₹ 40,00,000.00
₹ 47,20,000.00+18% GST
Quantity
Min 1 • Stock 50
| Product Name | Continuous Ambient Air Quality Monitoring Station EE-CAAQMS-05 (Sox, Nox, Co,Pm 10, Pm 2.5) |
| Brand | Unknown Brand |
| Product Code | ENE-0003 |
| Country of Manufacturer | IN |
| Weight | 1.000 |
| Category | Air Quality Monitor System |
| Test Certificate | No |
| Model | EE-CAAQMS-05 |
E&E's Air Quality Monitoring Station (AQMS) Is An Advanced System For Accurate Measurement And Logging Of Meteorological Parameters Including Temperature, Humidity, Wind Direction, Wind Speed, Visibility, UV Light, Light Intensity, And Solar Radiation. It Also Supports Optional Monitoring Of Air Pollutants Such As SO2, NO2, CO, CO2, O3, NH3, H2S, And PM 10 And PM2.5. Customizable To Specific Needs, These Stations Are Ideal For Applications In Agriculture, Hydrology, Ecology, And Meteorology. E&E Solutions Offers Expert Guidance In Selecting The Optimal Combination Of Sensors, Data Loggers, And Accessories To Meet Your Unique Requirements.
Features
Applications
| Product Specification | |
| Materials | Polycarbonate |
| Cover Screws | Stainless Steel, brass fitting |
| Ingress Protection | IP67 |
| Impact Resistance | IK08 |
| Rated Insulated Voltage | AC:220V |
| Ambient Temperature Range | -20°C to 60°C |
| Technology | |
| Module | Over air programming (OAP) of nodes at once (via Wi-Fi or 4G telemetry) |
| Communication | RS485 or printer cable for sensor suite to control unit, USB port for downloading data |
| File Output Format | Customizable (e.g., CSV, JSON) |
| Sensor Sox | |
| Principle | UV Fluorescence |
| Standard Range | Min: 0-100 ppb F.S. Mix: 0-20 ppm F.S. (Selectable) |
| Zero Noise | <0.4 ppb (RMS) |
| Span Noise | <2.5 ppb |
| Lower Detectable Limits | <0.5 ppb |
| Zero Drift (24 hrs) | <1ppb |
| Span Drift | <1% F.S. |
| Response Time | <80s (T90) |
| Precision | <1% |
| Linearity | <1% F.S. |
| Sample Flow Rate | 650 cc/min ±10% |
| Operating Temperature | 20-30°C range (per US EPA Guidelines) |
| NOX | |
| Principle | Chemiluminescence |
| Standard Range | Min: 0-100 ppb F.S. Mix: 0-20 ppm F.S. (Selectable) |
| Zero Noise | <0.4 ppb (RMS) |
| Span Noise | <2.5 ppb |
| Lower Detectable Limits | <0.4 ppb |
| Zero Drift (24 hrs) | <0.4 ppb |
| Span Drift | <1% F.S. |
| Response Time | <40s (T90) |
| Precision | <1% |
| Linearity | <1% F.S. |
| Sample Flow Rate | 500 cc/min ±10% |
| Operating Temperature | 20-30°C Range (As per USEPA Guidelines) |
| Carbon Monooxide (CO) | |
| Principle | Non-Dispersive infra-Red (NDIR) with Gas filter correlation/ cross Flow Modulation Method |
| Measurement | CO in Ambient Air |
| Display | Digital |
| Range | Auto ranging 0-100 ppm |
| Lower Detectable Limit | 0.1 ppm |
| Noise Level | 0.05 ppm with time constant ±30 seconds |
| Zero Drift | < 0.2 ppm/7 days |
| Span Drift | <1% fullscale in 24 hrs. |
| Linearity | Continous ±1% |
| Response Time | 50 seconds or less |
| Analog Output | 0 - 1V, 0-10V, 2-20mA/4-20mA |
| Digital Output | Multiple drop RS232 port, USB port/TCP/IP, Ethernet |
| PM10 and PM2.5 | |
| Principle | Beta Ray Attenuation |
| Resolution | 0.1 µgc |
| Lower Detectable Limit | 0.002 mg/m³ |
| Accuracy | <2% |
| Range | (0~1) mg/m3, (0~2)mg/m3, (0~5)mg/m3, (0~10)mg/m3 (selectable) |
| Sample Flow Rate | 16.L/min |
| Flow Accuracy | ±1% F.S. |
| Flow Stability | <±2%/24h(operation) |
| Calibration Film Reproducibility | <±2% |
| Sample Cycle | 60min (Optional) |
| Source | C14 source, active10µCi, exemption sourc |
| Filter Paper Tape | Glass Fiber |
| Roll Length | >20 meters |
| Detector | PMT |
| Met Station | |
| Ambient Temperature | Range: -10 - 60°C |
| Accuracy : ±0.2°C or better (with radiation Shield) | |
| Response Time : 10 sec | |
| Resolutions : 0.1 °C | |
| Relative Humidity | Range: 0 to 100%RH |
| Accuracy: ±3.0% or better | |
| Resolutions:1% | |
| Response Time: 10 sec | |
| Wind Speed | Range: 0 - 60 m/s |
| Sustainability: Upto 75 m/sec | |
| Accuracy: ± 0.5 m/sec | |
| Resolution:0.1 m/sec | |
| Threshold: 0.5 m/sec | |
| Response time:10 sec | |
| Wind Direction | Range: 0 - 359 degree |
| Accuracy: ± 3 degree | |
| Resolution: 1 degree | |
| Threshold: 0.5 m/sec | |
| Response time: 10 sec | |
| Rain Fall | Range:0.2 mm to 100 mm /hr |
| Accuracy: ± 5% | |
| Resolution: 0.2 mm | |
| Response time: 10 sec | |
| Solar Radiation | Range: 0 to 1500 W/m² |
| Accuracy: ± 5.0 % | |
| Resolution: 5W/m2 | |
| Power Source | |
| Battery | Rechargeable lithium-ion |
| Solar Panel Options | Internal Or External |
| External Solar Panel Mount | 45° Holder |
| Electrical Cable Connector | 2/3 Pins IP65 waterproof |
| Battery Warranty | 3 to 5 year for Rechargeable, 1 year for regular batteries |
| Board Power Voltages | 5.5V and 6.5.V |
| Maximum admitted Current (continuous) | 150mA |
| Maximum admitted Current (peak) | 300mA |
Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2. Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If buyer and seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2. Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis.
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
You're reviewing: Continuous Ambient Air Quality Monitoring Station EE-CAAQMS-05 (Sox, Nox, Co,Pm 10, Pm 2.5)
Your Rating *
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.