| Product Name | Alarm Valve - HD 247 | Wet Alarm Valve |
| Brand | HD |
| Product Code | jai-0046 |
| Country of Manufacturer | IN |
| Weight | 1.000 |
| Category | Alarm Valve |
| Hydrostatic Pressure Test | 35Kg./Sq.Cm. (500PSI) |
| System Type | CONVENTIONAL |
| Model | H |
| Mounting | Vertical |
| Approvals | UL Listed & FM Approved |
| Connection Ends | Flange X Flange Flange X Groove Groove X Groove |
| Trim | Galvanised fitting with Brass Valves |
| Nominal Size | 200, 150, 100 & 80 NB |
| Maximum Service Pressure | 17.5 Bar (250 PSI)* |
| THREADED OPENING | BSPT |
| Flange Connection | ANSI B16.42 #150 (Flange drilling matching to ANSI B 16.5#150) standard supply. Optional: ISO 7005-1 PN16 DIN 2501 PART-1 PN16 EN 1092-1 PN16 |
| Friction loss | 200 NB - 7.50 Mtrs. 150 NB - 7 Mtrs. 100 NB - 6.1 Mtrs. 80 NB - 4.7 Mtrs |
| finish | Red RAL 3001 |
| Reference | NFPA 13 and NFPA 25 |
DESCRIPTION
Alarm Valve is a double seated clapper check valve with grooved seat design, which ensures positive water flow for alarm operation and is designed for installation in wet pipe sprinkler system. External bypass prevents false alarm under all supply pressure
condition. In the event of variable pressure condition, false alarm is prevented with the provision of retard chamber, thus the design allows for installation under both variable and constant supply pressure condition. Operation of one or more automatic fire sprinklers causes the water to flow into the sprinkler system causing the alarm valve to open, allowing continuous flow of water into the system and transmittal of alarm, both electrical and mechanical.
OPERATION
The fire protection system initially when being pressurized, will allow water to flow into the system until water supply and system pressure is equalized and the clapper closes the waterway. Once the pressure is stabilized, the fire protection system is ready to be placed in service and then the alarm control valve must be opened. Under normal condition, the water pressure gauge connected to the system side of the alarm valve would show a higher or equal pressure reading than the water pressure gauge connected to the supply side of the valve. This occurs because of the bypass line connecting downstream and upstream side of the alarm valve, which allows water pressure surge to pass without lifting the valve clapper off its seat, thereby causing excessive high pressure surge entrapped in the system side due to presence of a check valve, which generally prevents false alarm.Sudden high pressure surge, as might be encountered by start-up of a large fire pump may lead the valve clapper to lift momentarily, allowing water to flowthrough grooves in the valve seat to the retard chamber. The water in the alarm line is automatically drained out, which helps to prevent false alarm due to successive transient surge in supply pressure. Restriction assembly located beneath the retard chamber consists of inlet and drain restriction orifices, which are established by considering the volume of the retard chamber to meet the listingand approval requirement with regard to time-to- alarm. These requirements represent a balancing ofthe need to reduce the possible false alarm due to a transient surge in supply pressure and to achieve desired minimum time- to- alarm following a sprinkler operation.
In constant pressure installation, the retard chamber is not required and the water passing through the groove in the alarm valve seat flows directly through restriction nozzle assembly to activate the mechanical and electrical alarm.
INSTALLATION
| Valve Size | Flange X Flange | Flange X Groove | Groove X Groove |
| 200 | 65 | 54.0 | 44.0 |
| 150 | 42 | 35.8 | 28.0 |
| 100 | 27 | 22.1 | 17.30 |
| 80 | 18 | 15.0 | 12.10 |
| NORMAL SIZE | Pipe OD in MM |
| 3” (80 NB | 89 |
| 4” (100 NB) | 114.3 |
| 6” (150 NB) | 165.1 |
| 6” (150 NB) | 168.3 |
| 8” (200 NB) | 219.1 |
��
Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2. Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If buyer and seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2. Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis.
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
You're reviewing: Alarm Valve - HD 247 | Wet Alarm Valve
Your Rating *
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.